• D Series

D Series

  • Elmwood Thermal Cut-Off
    Rely on more than 50 years of product experience
  • Contact form: single pole, open on temperature rise, not resettable
  • Design with switch and organic pellet
  • Rate load (resistive):
    16,7 A 250VAC, 10 A 12 VDC, 5 A 24 VDC
  • Approvals: VDE, UL, C-UL, CCC
  • Quality management: TS16949
  • Customized Solutions:
    Available is a broad range of customized solutions with
    formed leads, attached lead wires, terminals, insulation tubes and fixtures.
  • Operating temperatures:

TypeOperating Temperature TfHolding Temperature ThMax. Temperature Limit Tm at 250 VAC*
[°C][K][°C][°C]
D07072+0/-465115
D07677+0/-467150
D08184+0/-476115
D08890+0/-481150
D09093+0/-685315
D098100+0/-493130
D103104+0/-498315
D108109+0/-4103215
D115117+0/-4110130
D118121+0/-6113315
D125128+0/-4119300
D139141+0/-6134170
D142144+0/-6135315
D165169+0/-6162210
D172172+0/-5157280
D181184+0/-4174210
D192192+0/-5182250
D213216+0/-4210375
D213C216+0/-4212375
D226228+0/-6212240
D230230+0/-6212375
D242240+0/-6215375
D242C240+0/-6215375

*Max. temperature limits are in accordance to VDE approval.

Order data sheet