THERMONIE > HW Bimetall-Scheiben-Thermostate

T24M

  • Temperature limiter
  • Contact form: Single pole, open on temperature rise, manual reset
  • Calibration OFF temperature customizable from 50°C to 180°C in 1°C increments
  • Smallest calibration tolerance ±3 K
  • Factory preset fixed calibration temperature
  • Rated load for 1.000 cycles:
    16 A 250 VAC (resistive load)
    2,6 A 250 VAC (inductive load)
  • Maximum switch head temperature of 210°C
  • Mounting bracket electrically insulated
  • Quick connect, solder, and wire termination
  • Large selection of mounting brackets
  • Approvals: ENEC, UL, C-UL

T24

  • Thermostat, temperature limiter, or thermal cut-out
  • Contact form: Single pole open or close on temperature rise
  • Calibration OFF temperature customizable from 50°C to 205°C in 1°C increments
  • Differential between OFF and ON calibration temperature customizable from 7 K and 70 K
  • Smallest calibration tolerance ±2,5 K
  • Factory preset fixed calibration temperature
  • Rated load for 100,000 cycles:
    10 A 250 VAC (resistive load)
    1,6 A 250 VAC (inductive load)
  • Rated load for 10,000 cycles:
    16 A 250 VAC (resistive load)
    2,6 A 250 VAC (inductive load)
  • Maximum switch head temperature of 210°C
  • Mounting bracket electrically insulated
  • Quick connect, solder, and wire termination
  • Large selection of mounting brackets
  • Approvals: ENEC, UL, C-UL

T23

  • Thermostat, temperature control, or thermal cut-out
  • Height only 9,6 mm
  • Contact form: Single pole open or close on temperature rise
  • Calibration OFF temperature customizable from 50°C to 180°C in 1°C increments
  • Differential between OFF and ON calibration temperature customizable from 7 K to 70 K
  • Smallest calibration tolerance ±2.5 K
  • Factory preset fixed calibration temperature
  • Rated load for 100,000 cycles:
    10 A 250 VAC (resistive load)
    1,6 A 250 VAC (inductive load)
  • Rated load for 10,000 cycles:
    16 A 250 VAC (resistive load)
    2,6 A 250 VAC (inductive load)
  • Maximum switch head temperature of 180°C
  • Mounting bracket electrically insulated
  • Quick connect, solder, and wire termination
  • Large selection of mounting brackets
  • Approvals: VDE, UL, C-UL

H2M/33

  • Temperature limiter
  • Contact form: Single pole, open on temperature rise, manual reset
  • Calibration OFF temperature customizable from 45°C to 180°C in 1°C increments
  • Smallest calibration tolerance ±3 K
  • Factory preset fixed calibration temperature
  • Rated load for 10.000 cycles:
    16 A 250 VAC (resistive load)
    2,6 A 250 VAC (inductive load)
  • Maximum switch head temperature of 200°C
  • Mounting bracket electrically insulated
  • Quick connect, solder, and wire termination
  • Large selection of mounting brackets
  • Approvals: VDE, UL, C-UL

H2/33

  • Thermostat, temperature control, or thermal cut-out
  • Contact form: Single pole open or close on temperature rise
  • Calibration OFF temperature customizable from 45°C to 230°C in 1°C increments
  • Differential between OFF and ON calibration temperature customizable between 7 K and 75 K
  • Smallest calibration tolerance ±2.5 K
  • Factory preset fixed calibration temperature
  • Rated load for 100.000 cycles:
    10 A 250 VAC (resistive load)
    1,6 A 250 VAC (inductive load)
  • Rated load for 30.000 cycles:
    16 A 250 VAC (resistive load)
    2,6 A 250 VAC (inductive load)
  • Maximum switch head temperature is 230°C
  • Mounting bracket electrically insulated
  • Quick connect, solder, and wire termination
  • Large selection of mounting brackets
  • Approvals: VDE, UL, C-UL

H2/11

  • Thermostat, temperature control, or thermal cut-out
  • Contact form: Single pole open or close on temperature rise
  • Calibration OFF temperature customizable from 0°C to 50°C in 1°C increments
  • Differential between OFF and ON calibration temperature customizable between 7 K and 45 K
  • Smallest calibration tolerance is ±2.5 K
  • Factory preset fixed calibration temperature
  • Rated load for 100.000 cycles:
    10 A 250 VAC (resistive load)
    1,6 A 250 VAC (inductive load)
  • Rated load for 10.000 cycles:
    16 A 250 VAC (resistive load)
    2,6 A 250 VAC (inductive load)
  • Maximum switch head temperature is +170°C
  • Mounting bracket electrically insulated
  • Quick connect, solder, and wire termination
  • Large selection of mounting brackets
  • Approvals: VDE, UL, C-UL