Contact form: Single pole, open on temperature rise, manual reset
Calibration OFF temperature customizable from 50°C to 180°C in 1°C increments
Smallest calibration tolerance ±3 K
Factory preset fixed calibration temperature
Rated load for 1.000 cycles:
16 A 250 VAC (resistive load)
2,6 A 250 VAC (inductive load)
Maximum switch head temperature of 210°C
Mounting bracket electrically insulated
Quick connect, solder, and wire termination
Large selection of mounting brackets
Approvals: ENEC, UL, C-UL
T24
Thermostat, temperature limiter, or thermal cut-out
Contact form: Single pole open or close on temperature rise
Calibration OFF temperature customizable from 50°C to 205°C in 1°C increments
Differential between OFF and ON calibration temperature customizable from 7 K and 70 K
Smallest calibration tolerance ±2,5 K
Factory preset fixed calibration temperature
Rated load for 100,000 cycles:
10 A 250 VAC (resistive load)
1,6 A 250 VAC (inductive load)
Rated load for 10,000 cycles:
16 A 250 VAC (resistive load)
2,6 A 250 VAC (inductive load)
Maximum switch head temperature of 210°C
Mounting bracket electrically insulated
Quick connect, solder, and wire termination
Large selection of mounting brackets
Approvals: ENEC, UL, C-UL
T23
Thermostat, temperature control, or thermal cut-out
Height only 9,6 mm
Contact form: Single pole open or close on temperature rise
Calibration OFF temperature customizable from 50°C to 180°C in 1°C increments
Differential between OFF and ON calibration temperature customizable from 7 K to 70 K
Smallest calibration tolerance ±2.5 K
Factory preset fixed calibration temperature
Rated load for 100,000 cycles:
10 A 250 VAC (resistive load)
1,6 A 250 VAC (inductive load)
Rated load for 10,000 cycles:
16 A 250 VAC (resistive load)
2,6 A 250 VAC (inductive load)
Maximum switch head temperature of 180°C
Mounting bracket electrically insulated
Quick connect, solder, and wire termination
Large selection of mounting brackets
Approvals: VDE, UL, C-UL
H2M/33
Temperature limiter
Contact form: Single pole, open on temperature rise, manual reset
Calibration OFF temperature customizable from 45°C to 180°C in 1°C increments
Smallest calibration tolerance ±3 K
Factory preset fixed calibration temperature
Rated load for 10.000 cycles:
16 A 250 VAC (resistive load)
2,6 A 250 VAC (inductive load)
Maximum switch head temperature of 200°C
Mounting bracket electrically insulated
Quick connect, solder, and wire termination
Large selection of mounting brackets
Approvals: VDE, UL, C-UL
H2/33
Thermostat, temperature control, or thermal cut-out
Contact form: Single pole open or close on temperature rise
Calibration OFF temperature customizable from 45°C to 230°C in 1°C increments
Differential between OFF and ON calibration temperature customizable between 7 K and 75 K
Smallest calibration tolerance ±2.5 K
Factory preset fixed calibration temperature
Rated load for 100.000 cycles:
10 A 250 VAC (resistive load)
1,6 A 250 VAC (inductive load)
Rated load for 30.000 cycles:
16 A 250 VAC (resistive load)
2,6 A 250 VAC (inductive load)
Maximum switch head temperature is 230°C
Mounting bracket electrically insulated
Quick connect, solder, and wire termination
Large selection of mounting brackets
Approvals: VDE, UL, C-UL
H2/11
Thermostat, temperature control, or thermal cut-out
Contact form: Single pole open or close on temperature rise
Calibration OFF temperature customizable from 0°C to 50°C in 1°C increments
Differential between OFF and ON calibration temperature customizable between 7 K and 45 K
Smallest calibration tolerance is ±2.5 K
Factory preset fixed calibration temperature
Rated load for 100.000 cycles:
10 A 250 VAC (resistive load)
1,6 A 250 VAC (inductive load)
Rated load for 10.000 cycles:
16 A 250 VAC (resistive load)
2,6 A 250 VAC (inductive load)
Maximum switch head temperature is +170°C
Mounting bracket electrically insulated
Quick connect, solder, and wire termination
Large selection of mounting brackets
Approvals: VDE, UL, C-UL