Incorporated thermostat TU series
Contact form: Single pole single throw, open on temperature rise, or double-throw.
Adjusting temperature range: +30 to +90°C.
Incorporated thermal cut-out TU.RM FS series
Thermal cut-out with fail-safe sensing system (Type 2K in accordance to EN 60 730)
Contact form: Single pole single throw, open on temperature rise, manual reset
Calibration OFF temperature: +97°C
Calibration factory pre-set
Contact rating (per pole):
16 A 250 VAC (resistive load)
5 A 250 VAC (inductive load)
Thermal control and thermal cut-out connected in series
Plastic case with thermowell and cable gland
Internal termination: Quick connect terminals 6,3x0m,8 mm (Standard) or screw terminals.
Max. switch head temperature: 80°C,
Protection Class: IP40,
Colour of case: Brown, white or orange.
Colour of knob and cap: White or black.
Thermowell:
Material: Copper,
Thread: Brass, ½“ NPT,
Diameter: 8mm,
Length without thread: 90 mm (Standard), optional longer thermowell available.
Approvals: CE, incorporated thermostat only: ENEC (EN 60 730-1 and EN 60 730-2-9)
TS.SC
Pipe-Mount Temperature Limiter with Capillary Sensor
Thermal cut-out (Type 2B in accordance to EN 60 730)
Incorporated temperature limiter TS-RM series
Contact form: Single pole single throw, open on temperature rise, or double-throw, manual reset
Contact rating (open on rise switch):
16 A 250 VAC (resistive load)
5 A 250 VAC (inductive load)
Contact rating (open on rise switch):
0,5 A 250 VAC (resistive load)
Calibration OFF temperature can be set from +40°C to +110°C
Calibration factory pre-set
Plastic case with thermowell and cable gland
Internal termination: Quick connect terminals 6,3×0,8 mm or screw terminals (Standard).
Max. switch head temperature: 80°C,
Protection Class: IP40,
Colour of case: White, brown or orange,
Colour of cap: White or black,
Assembly with fitting spring to pipes with a diameter of 3/4″ to 3″.
Sensing Element:
Material: Stainless steel,
Approvals: CE, incorporated thermostat only: ENEC (EN 60 730-1 and EN 60 730-2-9)
TU.SC
Pipe mount thermostat (thermal control) with capillarry sensing element
Incorporated thermostat TU series
Contact form: Single pole single throw, open on temperature rise, or double-throw.
Rated load:
16 A 250 VAC (resistive load),
5 A 250 VAC (inductive load),
Adjusting temperature range: 30 to 90°C
Differential: 4 K
Plastic case with thermowell and cable gland
Internal termination: Quick connect terminals 6,3×0,8 mm or screw terminals (Standard).
Max. switch head temperature: 80°C,
Class II Control,
Protection Class: IP40,
Colour of case: White, brown or orange,
Colour of knob: White or black,
Assembly with fitting spring to pipes with a diameter of 3/4″ to 3″.
Sensing Element:
Material: Stainless steel,
Approvals: CE, incorporated thermostat only: ENEC (EN 60 730-1 and EN 60 730-2-9), UL
TU.SA IP54
Thermostat, thermal control
Incorporated thermostat TU series
Contact form: Single pole single throw, open on temperature rise, or double-throw.
Rated load:
16 A 250 VAC (resistive load),
5 A 250 VAC (inductive load),
Adjusting temperature range: -5 to 35°C, 0 to 40°C or 20 to 60°C
Plastic case with thermowell and cable sleeve
Internal termination: Quick connect terminals 6,3×0,8 mm or screw terminals (Standard).
Max. switch head temperature: 80°C,
Class II Control,
Protection Class: IP54,
Colour of case: Grey/Orange
Colour of knob: Orange
Sensing Element:
Material: Stainless steel,
Diameter: 30 mm
Approvals: CE, incorporated thermostat only: ENEC (EN 60 730-1 and EN 60 730-2-9), UL
TU.10 B
Thermostat, thermal control, or temperature limiter
Incorporated thermostat TU series
Contact form: Single pole single throw, open on temperature rise, or double-throw.
Rated load:
16 A 250 VAC (resistive load),
5 A 250 VAC (inductive load),
Adjusting temperature range: 0 to 60°C, 30 to 90°C, 30 to 110°C.
Plastic case with thermowell and cable gland
Internal termination: Quick connect terminals 6,3x0m,8 mm (Standard) or screw terminals.
Max. switch head temperature: 80°C,
Protection Class: IP40,
Colour of case: Brown, white or orange.
Colour of knob: White or black.
Thermowell:
Material: Copper,
Thread: Brass, ½“ NPT,
Diameter: 8mm,
Length without thread: 90 mm (Standard), optional longer thermowell available.
Approvals: CE, incorporated thermostat only: ENEC (EN 60 730-1 and EN 60 730-2-9), UL
TU.SA IP40
Thermostat, thermal control
Incorporated thermostat TU series
Contact form: Single pole single throw, open on temperature rise, or double-throw.
Rated load:
16 A 250 VAC (resistive load),
5 A 250 VAC (inductive load),
Adjusting temperature range: 4 to 40°C
Differential: 1,5 K
Plastic case with thermowell and cable sleeve
Internal termination: Quick connect terminals 6,3×0,8 mm or screw terminals (Standard).
Max. switch head temperature: 80°C,
Class II Control,
Protection Class: IP40,
Colour of case: White
Colour of knob: White or black
Sensing Element:
Material: Stainless steel,
Diameter: 30 mm
Approvals: CE, incorporated thermostat only: ENEC (EN 60 730-1 and EN 60 730-2-9), UL
TU.RM B FS
Thermal cut-out
Incorporated thermostat TU.RM FS series
Thermal cut-out with fail-safe sensing system (Type 2K in accordance to EN 60 730)
Contact form: Single pole single throw, open on temperature rise, manual reset
Contact rating (per pole):
16 A 250 VAC (resistive load)
5 A 250 VAC (inductive load)
Calibration OFF temperature can be set from +40°C to +110°C
Calibration factory pre-set
Plastic case with thermowell and cable gland
Internal termination: Quick connect terminals 6,3x0m,8 mm (Standard) or screw terminals,
Max. switch head temperature: 80°C,
Protection Class: IP40,
Colour of case: Brown, white or orange,
Colour of cap: White or black.
Thermowell:
Material: Copper,
Thread: Brass, ½“ NPT,
Diameter: 8mm,
Length without thread: 90 mm (Standard), optional longer thermowell available.
Approvals: CE, incorporated thermostat only: ENEC (EN 60 730-1 and EN 60 730-2-9)
TU.RM FS
Thermal cut-out with fail-safe sensing system (Type 2K in accordance to EN 60 730)
Contact form: Single pole single throw, open on temperature rise, manual reset
Contact rating (per pole):
16 A 250 VAC (resistive load)
5 A 250 VAC (inductive load)
Calibration OFF temperature can be set from +40°C to +335°C
Calibration factory pre-set
Max. switch head temperature: +150°C
Sensing system:
Standard length of capillary 900 mm or customer specific.
Material: Copper or stainless steel.
Bulb diameter: 3, 4, 5 or 6 mm.
Sensor length is customizable depending on material, diameter, and adjustable temperature range.
Diverse isolation tube materials (i.e. PVC or silicone-fiber glass) for the capillary tube.
Approvals: ENEC in accordance to EN 60 730-1 und EN 60 730-2-9
TU.RM
Thermal cut-out (Type 2B in accordance to EN 60 730)
Contact form: single pole (SPST), open on temperature rise, manual reset
Contact rating (per pole):
20 A 240 VAC (resistive load)
2,9 A 240 VAC (inductive load)
Calibration OFF temperature can be set from +40°C to +400°C
Calibration factory pre-set
Sensing system:
Standard length of capillary 900 mm or customer specific.
Material: Copper or stainless steel.
Bulb diameter: 3, 4, 5 or 6 mm.
Sensor length is customizable depending on material, diameter, and adjustable temperature range.
Diverse isolation tube materials (i.e. PVC or silicone-fiber glass) for the capillary tube.
Approvals: ENEC in accordance to EN 60 730-1 und EN 60 730-2-9, UL
DPL/MR
Thermal cut-out with fail-safe sensing system (Type 2K in accordance to EN 60 730)
Contact form: double pole (2PST), open on temperature rise, manual reset
Contact rating (per pole):
20 A 250 VAC (resistive load)
10 A 400 VAC (resistive load)
Calibration OFF temperature can be set from +85°C to +110°C
Caibration factory pre-set
Max. switch head temperature: +90°C
Sensing system:
Standard length of capillary 900 mm or customer specific.
Material: Copper or stainless steel.
Bulb diameter: 3, 4, 5 or 6 mm.
Sensor length is customizable depending on material, diameter, and adjustable temperature range.
Diverse isolation tube materials (i.e. PVC or silicone-fiber glass) for the capillary tube.
Approvals: UL
Um unsere Webseite für Sie optimal zu gestalten und fortlaufend verbessern zu können, verwenden wir Cookies. Durch die weitere Nutzung der Webseite stimmen Sie der Verwendung von Cookies zu.