J-2 Series

  • Thermal cut-out (SOD)
    A snap action thermostat that functions like a non-resettable type control.
    This single operation thermostat performs like a thermal fuse with the reliability
    of a 100{bbd499dde9524ef2df6a5e8e919f55dc4aadf745cb91d2165c90255fdca18de9} tested bimetallic thermal control.
  • Contact form: Single pole, single throw; open on temperature rise
  • Snap action device; quick break/quick make switching action
    Rated load:
    15 A 120 VAC (resistive load)
  • Calibration OFF temperature selectable from +60°C to +160°C in 1°C increments
  • Factory preset fixed calibration temperature
  • Calibration tolerance customizable from ±5 K to ±10 K
  • Maximum sensor head temperature of +180°C
  • Bimetallic element carries the circuit current
  • Integrated crimping connectors
  • Customization of the lead wire and insulation is possible

H Series

  • Thermal cut-out (SOD, bimetallic single operation device)
  • Contact form: Single pole, single throw; open on temperature rise
  • Snap action device; quick break/quick make switching action
  • Factory preset fixed calibration temperature
    PEPI
    Min. Calibration Temperature
    [°C]
    Max. Calibration Temperature
    [°C]
    Max. Current
    [A]
    Max. VoltageApprovals
    H Series1602408/8/4250 VAC/24/36 VDCTÜV/c-UL
    H-3 Series13023010/2250 VAC/24 VDCVDE/c-UL
    H-4 Series1302300,550 VDCVDE/c-UL
    H-5 Series13024015/10120/250 VACTÜV/c-UL
    H-7 Series20026015250 VACTÜV/c-UL
    H-8 Series25028015250 VAC/24 VDCTÜV/c-UL
  • Reset temperature: <-35°C

B Series

  • Thermostat, temperature control
  • Contact form: Single pole, single throw; open on temperature rise
  • Creep action device
  • Rated load:
    3 A 12 VDC
    3 A 24 VDC
  • Calibration OFF temperature selectable from +5°C to +150°C in 1°C increments
  • Factory preset fixed calibration temperature
  • Calibration tolerance customizable from ±5 K to ±10 K
  • Differential between OFF and ON calibration temperature of 2 K to 10 K
  • Bimetal does not carry current
  • Contacts are gold plated (also usable for applications with low voltage and small current)
  • Customization of lead wire and insulation possible
  • Approvals: UL, CSA

W Series

  • Thermal protector for use in all types of appliances and excellent for motor and winding protection
  • Contact form: Single pole, single throw; open on temperature rise
  • Snap action device; quick break/quick make switching action
  • Rated load:
    37 A 250 VAC (resistive load)
    10 A 250 VAC (inductive load)
  • Calibration OFF temperature selectable from +70°C to +150°C in 1°C increments
  • Factory preset fixed calibration temperature
  • Calibration tolerance customizable to either ±5 K or ±10 K
  • Differential, depending on chosen no-load calibration temperature, ranging between 10 K and 80 K
  • Maximum sensor head temperature +180°C
  • Bimetallic element carries the circuit current;
    current sensitivity can be customized using the specific resistance of the bimetal
  • Customization of lead wire and insulation is possible
  • Approvals: VDE, UL, CSA

N Series

  • Thermostat, temperature control
  • Contact form of models N, N-1, N-2: single pole, single throw; open on temperature rise
    Contact form of model NR: single pole, single throw; close on temperature rise
  • Creep action device
  • Rated load:
    8 A 12 VDC
    4 A 24 VDC
    Model N-1, N-2: Short circuit current until 100 A 12 VDC
  • Calibration OFF temperature selectable from
    +30°C to +130°C (Model N, N-1, N-2);
    +30°C to +125°C (Model NR); with 1°C increments
  • Factory preset fixed calibration temperature
  • Calibration tolerance customizable from ±3 K to ±10 K
  • No differential between OFF and ON calibration temperature, due to creep action contacts
  • Bimetal carries current
  • Current sensitivity customizable through the specific resistance of the sensing element (Models N, N-1, or N-2)
  • Contacts are gold plated (also usable for applications with low voltage and small current)
  • Customization of lead wire and insulation is possible
  • Approvals: UL, C-UL

C Series

  • Thermostat, temperature control
  • Contact form of models C and CH: single pole, single throw; open on temperature rise
    Contact form of model CR: single pole, single throw; close on temperature rise
  • Creep action device
  • Rated load:
    8 A 12 VDC
    4 A 24 VDC
  • Calibration OFF temperature selectable from +5°C to +200°C in 1°C increments
  • No differential between OFF and ON calibration temperature, due to creep action contacts
  • Bimetal carries current
  • Contacts are gold plated (also usable for application with low voltage and small current)
  • Customization of lead wire and insulation is possible
  • Approval: UL, CSA

V Series

  • Temperature control, usable as i.e. charge and short circuit protection in battery packs
  • Contact form: Single pole, single throw; open on temperature rise
  • Snap action device; quick break/quick make switching action
  • Rated load:
    10 A 12 VDC 10,000 cycles
    5 A 24 VDC 10,000 cycles
    Short circuit currents until:
    150 A 12 VDC 500 cycles
  • Calibration OFF temperature selectable from +45°C to +100°C in 1°C increments
  • Factory preset fixed calibration temperature
  • Calibration temperature tolerance customizable ±5 K to ±10 K
  • Differential, depending on no-load calibration temperature, ranging from 4 K to 35 K; switch back temperature: >35°C
  • Bimetallic element carries the circuit current;
    current sensitivity can be customized using the specific resistance of the bimetal (model V or VA)
  • Contacts are gold-plated
  • Customization of lead wire and insulation is possible
  • Approvals: UL, CSA

ST01 Series

  • Temperature limiter, excellent for motor and winding protection, and a large variety of appliances
  • Contact form: Single pole, single throw; open or close on temperature rise
  • Snap action device; quick break/quick make switching action
  • Rated load:
    6,3 A 250 VAC (resistive load)
    5 A 125 VAC (resistive load)
  • Calibration OFF temperature selectable
    from +60°C to +180°C in increments of 5°C
  • Factory preset fixed calibration temperature
  • Calibration tolerance: ±5 K
  • Differential 20 to 50 K depending on the chosen calibration temperature
  • Maximum sensor head temperature of +200°C
  • Low current sensitivity, the bimetallic element does not carry the circuit current
  • Termination: Lead wire gauge 0,325 mm² (AWG 22) either with
    XLPE isolation (150°C, 300 V) or PFA isolation (250°C, 600 V),
    alternatively lead wire gauge 0,205 mm² (AWG 24) wit Silicone isolation (200°C, 600 V),
    or solid bare wire (lead frame) for PCB assembly
  • Approvals: VDE, UL, C-UL

JS Series

  • Temperature limiter (self-holding)
    Under fault condition it opens the circuit and holds it open using an electric heat source until power is removed
  • Contact form: Single pole, single throw; open on temperature rise (self-holding)
  • Snap action device; quick break/quick make switching action
  • Rated load:
    13 A 250 VAC (resistive load)
    5 A 250 VAC (inductive load)
    15 A 120 VAC
  • Calibration OFF temperature selectable from +50°C to +160°C in 1°C increments
  • Compact design with completely integrated heating resistance
  • Factory preset fixed calibration temperature
  • Calibration temperature tolerance customizable from ±5 K to ±10 K
  • Maximum sensor head temperature of +180°C
  • Bimetallic element carries the circuit current;
    current sensitivity can be customized using the specific resistance of the bimetal
  • Integrated crimping connectors
  • Customization of the lead wire and insulation is possible
  • Approvals: VDE, UL, C-UL

J Series

  • Thermal protector, excellent for motor and winding protection, and ballast for tubular fluorescent lamps
  • Contact form: Single pole, single throw; open on temperature rise
  • Snap action device; quick break/quick make switching action
  • Rated load:
    13 A 250 VAC (resistive load)
    5 A 250 VAC (inductive load)
    5 A 24 VDC
    10 A 12 VDC
  • Calibration OFF temperature selectable from +50°C to +160°C in 1°C increments
  • Factory preset fixed calibration temperature
  • Calibration tolerance customizable from ±4 K to ±10 K
  • Differential of 10 K to 70 K depending on the calibration temperature
  • Maximum sensor head temperature of +180°C
  • Bimetallic element carries the circuit current;
    current sensitivity can be customized using the specific resistance of the bimetal
  • Integrated crimping connectors
  • Customization of the lead wire and insulation is possible
  • Approvals: VDE, UL, CSA