RD Series

  • Elmwood Thermal Cut-Off with ceramic bracket
    Rely on more than 50 years of product experience
  • Contact form: single pole, open on temperature rise, not resettable
  • Design with switch and organic pellet
  • Termination: Quick connect terminal 6,3×0,8 mm
  • Bracket: mounting hole diameter 4,7 mm
  • Rate load (resistive):
    16,7 A 250VAC, 10 A 12 VDC, 5 A 24 VDC
  • Approvals: VDE, UL, C-UL, CCC
  • Quality management: TS16949
  • Operating temperatures:

TypeOperating Temperature TfHolding Temperature ThMax. Temperature Limit Tm at 250 VAC
[°C][K][°C][°C]
RD07072+0/-465115
RD07677+0/-467150
RD08184+0/-476115
RD08890+0/-481150
RD09093+0/-685315
RD098100+0/-493130
RD103104+0/-498315
RD108109+0/-4103215
RD115117+0/-4110130
RD118121+0/-6113315
RD125128+0/-4119300
RD139141+0/-6134170
RD142144+0/-6135315
RD165169+0/-6162210
RD172172+0/-5157280
RD181184+0/-4174210
RD192192+0/-5182250
RD213216+0/-4210375
RD213C216+0/-4212375
RD226228+0/-6212240
RD230230+0/-6212375
RD242240+0/-6215375
RD242C240+0/-6215375

*Max. temperature limits are in accordance to UL approval.

PD Series

  • Elmwood Thermal Cut-Off with plastic case
    Rely on more than 50 years of product experience
  • Contact form: single pole, open on temperature rise, not resettable
  • Design with switch and organic pellet
  • Termination: Quck connect terminal 6,3×0,8 mm
  • Bracket: hook on XXX mm metall sheet
  • Rate load (resistive):
    16,7 A 250VAC, 10 A 12 VDC, 5 A 24 VDC
  • Approvals: VDE, UL, C-UL, CCC
  • Quality management: TS16949
  • Operating temperatures:

TypeOperating Temperature TfHolding Temperature ThMax. Temperature Limit Tm at 250 VAC*
[°C][K][°C][°C]
PD07072+0/-465115
PD07677+0/-467150
PD08184+0/-476115
PD08890+0/-481150
PD09093+0/-685315
PD098100+0/-493130
PD103104+0/-498315
PD108109+0/-4103215
PD115117+0/-4110130
PD118121+0/-6113315
PD125128+0/-4119300

*Max. temperature limits are in accordance to VDE approval.

 

JD Series

  • Elmwood Thermal Cut-Off with bracket
    Rely on more than 50 years of product experience
  • Contact form: single pole, open on temperature rise, not resettable
  • Design with switch and organic pellet
  • Termination: Quick connect terminal 4,8×0,5 mm (Standard) or 6,3×0,8 mm
  • Bracket: mounting hole diameter 5 mm
  • Rate load (resistive):
    16,7 A 250VAC, 10 A 12 VDC, 5 A 24 VDC
  • Approvals: UL, C-UL, VDE (incorporated TCO only)
  • Quality management: ISO9001, TS16949
  • Operating temperatures:

TypeOperating Temperature TfHolding Temperature ThMax. Temperature Limit Tm at 250 VAC*
[°C][K][°C][°C]
JD07072+0/-465115
JD07677+0/-467150
JD08184+0/-476115
JD08890+0/-481150
JD09093+0/-685315
JD098100+0/-493130
JD103104+0/-498315
JD108109+0/-4103215
JD115117+0/-4110130
JD118121+0/-6113315
JD125128+0/-4119300
JD139141+0/-6134170
JD142144+0/-6135315
JD165169+0/-6162210
JD172172+0/-5157280
JD181184+0/-4174210
JD192192+0/-5182250
JD213216+0/-4210375
JD226228+0/-6212240
JD230230+0/-6212375
JD242240+0/-6215375

*Max. temperature limits are in accordance to VDE approval.

I Series

  • Elmwood Thermal Cut-Off
    Rely on more than 50 years of product experience
  • Rectangle case improves the response time significantly
    in case the thermal cut-off is assembled to a flat plane
  • Contact form: single pole, open on temperature rise, not resettable
  • Design with switch and organic pellet
  • Rate load (resistive):
    16,7 A 250VAC, 10 A 12 VDC, 5 A 24 VDC
  • Approvals: VDE, UL
  • Quality management: TS16949
  • Customized Solutions:
    Available is a broad range of customized solutions with
    formed leads, attached lead wires, terminals, insulation tubes and fixtures.
  • Operating temperatures:

TypeOperating Temperature TfHolding Temperature ThMax. Temperature Limit Tm at 250 VAC*
[°C][K][°C][°C]
i07072+0/-465115
i07677+0/-467150
i08184+0/-476115
i08890+0/-481150
i09093+0/-685315
i098100+0/-493130
i103104+0/-498315
i108109+0/-4103215
i115117+0/-4110130
i118121+0/-6113315
i125128+0/-4119300
i139141+0/-6134170
i142144+0/-6135315
i165169+0/-6162210
i172172+0/-5157280
i181184+0/-4174210
i192192+0/-5182250
i213216+0/-4210375
i213C216+0/-4212375
i226228+0/-6212240
i230230+0/-6212375
i242240+0/-6215375
i242C240+0/-6215375

*Max. temperature limits are in accordance to VDE approval.

D Series

  • Elmwood Thermal Cut-Off
    Rely on more than 50 years of product experience
  • Contact form: single pole, open on temperature rise, not resettable
  • Design with switch and organic pellet
  • Rate load (resistive):
    16,7 A 250VAC, 10 A 12 VDC, 5 A 24 VDC
  • Approvals: VDE, UL, C-UL, CCC
  • Quality management: ISO9001, IATF16949
  • Customized Solutions:
    Available is a broad range of customized solutions with
    formed leads, attached lead wires, terminals, insulation tubes and fixtures.
  • Operating temperatures:

TypeOperating Temperature TfHolding Temperature ThMax. Temperature Limit Tm at 250 VAC*
[°C][K][°C][°C]
D07072+0/-457115
D07677+0/-462150
D08184+0/-469115
D08890+0/-475150
D09093+0/-678315
D098100+0/-485130
D103104+0/-489315
D108109+0/-494215
D110110+0/-595150
D115117+0/-4102130
D118121+0/-6106315
D125128+0/-4113300
D139141+0/-6126170
D142144+0/-6129315
D156156+0/-5141170
D165169+0/-6154210
D172172+0/-5157280
D181184+0/-4169210
D192192+0/-5182250
D213216+0/-4201375
D226228+0/-6212240
D230230+0/-6212375
D242240+0/-6215375
D257257+0/-5220375

*Max. temperature limits are in accordance to VDE approval.