• H2/11

H2/11

  • Thermostat, temperature control, or thermal cut-out
  • Contact form: Single pole open or close on temperature rise
  • Calibration OFF temperature customizable from 0°C to 50°C in 1°C increments
  • Differential between OFF and ON calibration temperature customizable between 7 K and 45 K
  • Smallest calibration tolerance is ±2.5 K
  • Factory preset fixed calibration temperature
  • Rated load for 100.000 cycles:
    10 A 250 VAC (resistive load)
    1,6 A 250 VAC (inductive load)
  • Rated load for 10.000 cycles:
    16 A 250 VAC (resistive load)
    2,6 A 250 VAC (inductive load)
  • Maximum switch head temperature is +170°C
  • Mounting bracket electrically insulated
  • Quick connect, solder, and wire termination
  • Large selection of mounting brackets
  • Approvals: VDE, UL, C-UL
Order data sheet